AisaFENIX is optimized for the most demanding defense, law enforcement, and environmental applications. In a single continuous image, AisaFENIX delivers the best hyperspectral data ever seen over VNIR, NIR, and SWIR wavelengths. Its rugged, compact design is ideal for turret and UAV installations.

AisaFENIX is the most versatile HSI unit for field, airborne and ground vehicle use. It delivers unprecedented performance over the entire visible, NIR, and SWIR spectral ranges. AisaFENIX is designed for simplicity, reliability and performance in field usage. Patent pending imaging spectrograph, optimized mechanical structure, and passive temperature compensation make the instrument one of the most stable hyperspectral imagers.

Spectral CameraVNIRSWIR
SpectrographHigh efficiency transmissive imaging spectrograph. Throughput practically independent of polarization. Smile and keystone < 0.2 pixels.High efficiency transmissive imaging spectrograph. Throughput practically independent of polarization. Smile and keystone < 0.2 pixels.
Numerical ApertureF/2.4F/2.4
Spectral Range380-970 nm970-2500 nm
Spectral Resolution3.5 nm10 nm
CalibrationSensor provided with wavelength and radiometric calibration file.Sensor provided with wavelength and radiometric calibration file.
FOV32.3 degrees32.3 degrees
IFOV0.084 degrees0.084 degrees
Swath Width0.58 x altitude0.58 x altitude
Altitude for 1 m pixel size660 m660 m
DetectorCMOSStirling cooled MCT
Spectral Binning Options2x, 4x or 8x-
Number of Spectral Bands244, 172 or 86275
Spectral sampling/band1.75 nm, 3.5 nm, or 7 nm6 nm
Frame rate, up to (frames/s)130130
Spatial Pixels384384
Output12 bits CL16 bits CL
SNR500-1000:1 (peak)900:1 (peak)
Integration timeAdjustable, within frame timeAdjustable, within frame time
ShutterElectromechanical shutter for dark background registration, user controlled by softwareElectromechanical shutter for dark background registration, user controlled by software
Operating modesHyperspectral and multispectral. The operator can create application specific band configurations and quickly change from one mode or configuration to others in flight operation.Hyperspectral and multispectral. The operator can create application specific band configurations and quickly change from one mode or configuration to others in flight operation.
Typical Power Consumption150 W150 W
Maximum Power Consumption500 W500 W